Bienvenido a b2b168.com, Ingreso libre | Inicia sesión
中文(简体) |
中文(繁體) |
English |Francés |Deutsch |Pусский |
| No.13668539

- Casa
- Conductores de alimentación
- Comprar Cables
- Acerca de nosotros
- Productos
- Noticia
- Mensaje
- Contactos
- Categorías de productos
- Enlaces interesantes
PHILIPS Philips EPIQ 7 abdominal probe C5-1 ultra high-definition images
2015-03-14 Reads : 20
Official website: http: //www.zhihengmed.com specialized ultrasound, maintenance, upgrades, maintenance-stop service provider - Guangzhou Shiko 24-hour service hotline: 4000-813-989 / 138-244-50510 Machine Model: EPIQ 7 (with Series EPIQ 5) 1. Symptom 1) Philips EPIQ 7 machine can start, in the selection of the phased array probe (S5-1), the image area is not the beginning of the wave, only noise, ultrasound scan can not diagnose. 2) then switch to the linear array probe (L11-3), there is the beginning of the wave in the image area, but under normal circumstances, only about one-third, the far-field section does not echo. Increasing the gain, noise will be increased, can not be clinically diagnosed. The image on the monitor is shown in Figure 2. 2. Analysis of maintenance a) analysis to determine the presence of a fault ultrasonic transmitter part, suspect the system according to the symptoms. Generating and transmitting ultrasonic components affected include: probe, channel plate, firing board, the front control panel and high-voltage power supply, so the need to gradually checking further narrow the scope of failure. 2) First, check the probes. Unplug the probe, insert another outlet, and then look to switch the probe is normal. After examination, the probe is switched to normal, symptom persists. This shows that the probe, the channel plate this part of normal operation. 3) Next, check the transmitted pulse trigger signal, the result is normal. Upon detection of high voltage power supply, and found no +/- 80V power output. This suggests that the presence of high voltage power supply failure. 4) high-voltage power failure will result in emission of ultrasonic pulse output board can not produce, it can not have a start-wave image. 3. Troubleshooting 1) high-voltage power supply module from the chassis to remove, open the metal casing, use a multimeter testing found that there are two fuse has blown, indicating high voltage power supply internal short circuit fault. After measurement, found two transistors shorted breakdown. Replacement of the same specifications as the transistor and the fuse, short circuit troubleshooting. After the high-voltage power supply module into the machine, turn on the computer, the system returns to normal. EPIQ 7 match Philips ultrasound probe: C10-4ec, S7-3t, C10-3v, C9-2, V6-2, C8-5,3D9-3v, C5-1, X5-1 (volume phased array), L18 -5, X6-1, L15-7io, L12-5, L12-3, S12-4, X7-2, X7-2t
palabras clave: EPIQ, 7 ultrasound repair, cardiovascular ultrasound, Philips, epiq7 new original probe,
administración>>>
Usted es el 27440 visitante
derechos de autor © GuangDong ICP No. 10089450, Guangzhou Shiko mantenimiento de equipos médicos Servicios SA Todos los Derechos Reservados.
apoyo técnico: Shenzhen Allways tecnología desarrollo Co., Ltd.
AllSources red'sDescargo de responsabilidad: La legitimidad de la información de la empresa no asume ninguna responsabilidad de garantía
Usted es el 27440 visitante
derechos de autor © GuangDong ICP No. 10089450, Guangzhou Shiko mantenimiento de equipos médicos Servicios SA Todos los Derechos Reservados.
apoyo técnico: Shenzhen Allways tecnología desarrollo Co., Ltd.
AllSources red'sDescargo de responsabilidad: La legitimidad de la información de la empresa no asume ninguna responsabilidad de garantía